Dataplex DPX-213 Especificações Página 23

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 51
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 22
HYDROLOGICAL SERVICES
DL3 100-023 IMP
Issue 2: 15/11/2005
4.1.7 Date/Time Parameters (D, T, TO)
The logger date and time is maintained in a battery backed Real Time Clock whose time base is
adjustable by a trim capacitor on the circuit board. Time is displayed in 24 hour format separated by
colons, and the date is displayed as day/month/year with slash separators. When entering the time
and date all fields must be entered. Note that if the time is entered as T= then it will be reset to
midnight 00:00:00.
On-line Help
T?
Time: Use 24 hour time format with colon separator
Syntax: T<CR> Displays hardware time
T=9:45:0<CR> Sets the time (Note: Leading 0's are optional but
T=16:25:26<CR> hrs+mins +secs must be entered)
On-line Help
D?
Date: Use Mn/Dy/Yr format with slash separator
Syntax: D<CR> Displays hardware date
D=3/4/92<CR> Sets date (Note: Leading 0's are optional but
D=10/25/92<CR> mo+day+yr must be entered)
The Time Offset parameter allows data from loggers in different time zones to be synchronised to a
reference time zone location. If this feature is not required then simply set the time offset to 00:00.
On-line Help
TO?
Time Offset: Hardware Time + Time Offset = Software Time/Date
Note: Events are time stamped to H/W time,
mesg time stamped at S/W time
(If TO=00:00 then S/W Time/Date = H/W Time/Date)
Syntax: TO<CR> Displays the current Time Offset
TO=09:30<CR> Sets the Time Offset parameter (Note: Leading 0's
must be entered)
Vista de página 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 50 51

Comentários a estes Manuais

Sem comentários